Filter Results By:

Products

Applications

Manufacturers

High Voltage Probes

handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.

See Also: High Voltage Meters


Showing results: 121 - 135 of 143 items found.

  • Injection Transformer

    J2101A - PICOTEST Corp.

    The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

  • Injection Transformer

    J2100A - PICOTEST Corp.

    The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.

  • LISN & Voltage Probes

    Laplace Instruments Ltd.

    All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.

  • Isolated Hall Effect Current Sensors

    Vektrex Electronic Systems

    Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.

  • High Impedance Active Probes

    12C - Picoprobe

    A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.

  • Portable Holiday Detectors

    Helmut Fischer AG

    Maximum safety with high voltage generation directly in the probe head and low-energy voltage according to ISO 2746Three instrument versions with different test voltage ranges:HV5: 0.8 5 kVHV20: 4 20 kVHV40: 8 40 kVIntuitive operation with menu navigation, rotary push switch and OLED displayExtensive selection of electrodesDisplay of the test voltage applied directly to the electrode Pore detection sensitivity: detection threshold settable to a voltage drop of 10, 20, 30 or 50 %Porosity detector switchable between static and dynamic thresholdBattery operation by means of a Li-ion battery with smart battery technology, a controller monitors the battery state permanently and avoids deep discharge

  • OverHead Lines Contact Voltage & Low Voltage Indicator

    LVD-415 - Standard Electric Works Co., Ltd

    ● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.

  • Infared ThermometersS

    IR-L 300 / IR-L 550 / IR-L 900 / IR-L 1000 - Kusam Electrical Industries Limited

    Infra Red Thermometer can be used in places where it is difficult for a normal temperature probe to reach or places where it is dangerous such as Heat Treatment Furnance, High Voltage Operating Plants, Molten Metal Temperature Monitoring, Kiln Temperature, Bearing Temperature, Energy Conservation, Scientific Experiment, Research & Development, Air conditioning, Petrochemicals, Automobile repair & Maintenance.

  • HV Calibration

    B-1027 - ROSS ENGINEERING CORPORATION

    Ross Engineering Corporation’s High Voltage Calibration Lab provides high accuracy capability for conducting tough reliability tests on all our high voltage devices. In this facility we test and calibrate HV Relays, HV Dividers, HV Probes, Spark Gaps, our Fiber Optic Systems, and HV Digital Voltmeters up to 450kV. We provide our own in house test lab to ensure Ross products meet or exceed required safety standards as well as our own high standards of dependability, long life and quality. Our technicians use test equipment calibrated by or traceable to National Institute of Standards and Technology or other national metrology institute to provide the highest in testing accuracy.

  • Low Voltage Differential Oscilloscope Probes

    Tektronix, Inc.

    Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!

  • 12 Function True RMS Multimeter + NCV

    Extech EX355 - Extech Instruments Corporation

    The EX355 is a professional DMM loaded with advanced features and functions. Low Impedance (LoZ) mode eliminates false readings caused by ghost voltages. Low Pass Filter (LPF)attenuates high frequencies to reduce noise for accurate readings. True RMS provides accurate readings when measuring distorted or noisy waveforms. Built-in Non-Contact AC Voltage Detector quickly checks for the presence of AC Voltage before testing. Features a 6000 count LCD display, data hold, min-max, relative mode, capacitance zero, auto power off, continuity and diode test. This meter will measure AC/DC voltage to 600 V and AC/DC current to 10 amps. Complete with test leads, general purpose bead wire temperature probe, manual and two AA batteries.

  • Differential Voltage Probes

    DP150/DP200pro - Powertek LLC

    The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.

  • Insulation Resistance Tester For PV (Judge Deterioration Point)

    MIS-PVS - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PVS is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester For PV (4 Range)

    MIS-PV2 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV2 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

  • Insulation Resistance Tester for PV (2 range)

    MIS-PV1 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    The model MIS-PV1 is an insulation resistance tester for the exclusive use in photovoltaic systems. The ordinary insulation resistance testers cannot make measurement properly during generation of PV systems. This instrument, however, can measure the insulation resistance simply by touching probe to the live line whether making generation or not. There are two ranges of PVH and PVL. PVH is for high voltage generation system (more than 500V and less than 1000V) and PVL is for the system less than 500V.

Get Help